kW output
Alternative manual calculation:
measure the width, length and height of your room
multiply the three measurements together.
e.g. width 4m x length 5m x height 2m = 40 cubic metres.
If your room or house is new build and fitted with very good insulation then divide the room volume by 25 = 1.6 kW nominal required
If the room has average insulation then divide by 15 = 2.66 kW (this is the normally given figure, as in the calculator).
If the insulation is poor, then divide the room volume by 10 = 4 kW
If you choose a stove with a kW rating significantly higher than the output given in the calculation, then the stove could be unbearably hot in that room, and it will not be an efficient use of fuel.
For open staircases, you may find nearly all of the heat escapes upstairs.
Some manufacturers give maximum outputs or an output range such as “3-11kw”. However, if you run your stove with all vents fully open, to achieve the theoretical maximum figure; it would burn through lots of wood very quickly. Choose a stove based on the nominal output.
Sometimes maximum outputs are wildly exaggerated – e.g. the Chinese stoves that you’ll see on ebay with small fireboxes and fake CE plates. A stove’s maximum output is proportional to the size of the combustion chamber – the more wood you can get in, the higher the kW.
Sometimes manufacturers will specify the closing of the air inlets to gain a higher efficiency rating during the CE test. The nominal output will be quite low in that case compared to the size of the stove, the actual output and real world efficiency can be much lower.