500mm Flue Pipe / Matt Black
Heavy gauge steel pipe with matt black painted finish.
440 mm Effective length, can be cut to length.
Robust construction of 2mm thick Steel, Type EN 10025
Robust construction of 2mm thick Steel, Type EN 10025
Air tight flush fitting joints (N1 / 40 Pa).
For solid fuel appliances tested to temperatures up to 500 degrees C.
Used to connect the stove and Flue Liner / Chimney Stack / Twin Wall Flue System.
CANNOT be used to pass through ceilings or walls, or outdoors.
INSTALLATION
Distance to combustible materials (including fire rated plaster board): 500 mm minimum (or UK regs state > 3 times the diameter of the flue,
150mm diameter Flue Pipe should be 450mm away from combustible materials.
The smaller spigot end should be pointing downward to allow water to flow within the pipe.
Joints can be sealed with a fine jointing compound (flueseal, ceramix, fire cement is too coarse). Joins between the flue pipe and stove, and between the flue pipe and twin wall chimney or flue liner, may require a fire proof glass rope also.
MAINTENANCE
Inspect the chimney at least every 6 months and clean every 12 months, more often when using coal.
Use a pipe with an access door, or clean from within the stove when possible.
Colour | Black |
---|---|
CE Rating | EN 1856-2-T400-N1-D-VmL01200-G500 |
Diameter | 150mm |
Length | 500 mm |
Wall Thickness | 2 mm |
Type (EU / UK) | European |