500mm EU to UK Converter Flue Pipe & 500mm Adjustable/Telescope Pipe **DUO OFFER**
500mm Starter pipe and 500mm adjustable/telescopic pipe - special offer price for pair (combined price when sold separately is £70).
The European starter pipe fits neatly around the flue outlets of contemporary stoves.
The internal drip bead ensures EU type stove outlets conform to UK regulations.
The telescopic/adjustable pipe is essential for any installation: Stoves cannot be removed without dismantling the chimney if you don't use an adjustable flue pipe.
Total combined length adjusts from 550 up to 950mm.
Internal diameter 150mm.
EU regulations require the pipe fitting around the outside of the flue exit / spigot to allow the smooth flow of the flue gasses. UK regs have it on the inside to let water run into the stove.
The euro pipe has a flange on the inside of the pipe that acts as a drip bead which causes water to fall inside the stove's flue exit. Each subsequent pipe fits inside the pipe below, thereby converting the EU fitment to a UK standard pipe layout.
Use the enclosed bracket to secure the Adjustable Pipe to the required length.
Fill any gap between the adjustable pipe and the fixed length pipe with either Fire Cement or High Temperature Sealant.
Details:
European type heavy gauge steel pipe with matt black painted finish.
Robust construction of 2mm thick Steel, Type EN 10025
For solid fuel appliances, tested to temperatures up to 500 degrees C.
Used to connect the stove and Flue Liner / Chimney Stack / Twin Wall Flue System.
CANNOT be used to pass through ceilings or walls, or outdoors.
INSTALLATION
Distance to combustible materials: 3 times the diameter of the flue, (wood, plaster board, etc.)
150mm diameter Flue Pipe should be 450mm away from combustible materials.
The smaller spigot end should be pointing downward to allow water to flow within the pipe. (UK building regs)
Joints can be sealed with a fine jointing compound (flueseal, ceramix). Joins between the flue pipe and stove and between the flue pipe and twin wall chimney or flue liner may require a fire proof glass rope also.
MAINTENANCE
Inspect the chimney every 6 months minimum and clean every 12 months, possibly more often when using coal.
Colour | Black |
---|---|
CE Rating | EN 1856-2-T400-N1-D-VmL01200-G500 |
Diameter | 150mm |
Length | 500 mm |
Wall Thickness | 2 mm |
Type (EU / UK) | European |